文章摘要
冯 芃,金星爱,吕 晶,裴丽玲,孟祥玲,刘英群.两种牙体充填材料对乳牙边缘微渗漏及固化效率的体外研究[J].,2019,19(5):872-875
两种牙体充填材料对乳牙边缘微渗漏及固化效率的体外研究
Evaluation of Microleakage and Polymerization Efficiency in Primary Teeth with Two Different Restorative Material
投稿时间:2018-05-23  修订日期:2018-06-20
DOI:10.13241/j.cnki.pmb.2019.05.017
中文关键词: 纳米瓷有机充填材料  乳牙  微渗漏  固化效率
英文关键词: Composan LCM  Primary teeth  Micro-leakage  Curing efficiency
基金项目:黑龙江省自然科学基金项目(H2016037)
作者单位E-mail
冯 芃 哈尔滨医科大学附属第一医院儿童口腔科 黑龙江 哈尔滨 150000 2416399683@qq.com 
金星爱 哈尔滨医科大学附属第一医院儿童口腔科 黑龙江 哈尔滨 150000  
吕 晶 哈尔滨医科大学附属第一医院儿童口腔科 黑龙江 哈尔滨 150000  
裴丽玲 哈尔滨医科大学附属第一医院儿童口腔科 黑龙江 哈尔滨 150000  
孟祥玲 黑龙江省口腔病防治院 黑龙江 哈尔滨 150000  
刘英群 哈尔滨医科大学附属第一医院儿童口腔科 黑龙江 哈尔滨 150000  
摘要点击次数: 1031
全文下载次数: 820
中文摘要:
      摘要 目的:比较纳米瓷充填材料和复合树脂充填乳牙V类洞边缘微渗漏的影响以及固化效率的差异。方法:第一部分为微渗漏实验,选取滞留拔除的上颌乳前牙20颗,唇侧制备V 类洞,随机分为A、B两组,分别用Composan LCM和FiltekTM Z350充填,亚甲基蓝染色处理,24 h后使用体式显微镜观察,测量染料渗入深度为微渗漏值,每组各选2个样本扫描电镜观察充填体与牙体组织间粘结情况。第二部分为显微硬度实验,分别用两种充填材料制作模块各9个,记为A、B两组,材料模块光固化24 h后使用显微硬度仪检测充填材料的固化效率。结果:Composan LCM组微渗漏值明显低于FiltekTM Z350组(P<0.05);扫描电镜下观察FiltekTM Z350组充填材料与牙体组织间可见裂缝,界面参差不齐,有不连续的小断裂,Composan LCM组界面连续均匀,未见明显裂缝;两组充填材料的固化效率无显著差异(P>0.05)。结论:纳米瓷充填材料和复合树脂均可用于乳牙龋洞充填,使用纳米瓷充填材料可减少微渗漏。
英文摘要:
      ABSTRACT Objective: To evaluate the efficiency of Composan LCM and FiltekTM Z350 on the micro-leakage of Class V cavities. Methods: Part 1: 20 samples of retained maxillary primary incisors were collected, Class V cavities on the buccal surfaces were prepared and randomly divided into two groups. Group A and group B were filled with Composan LCM and FiltekTM Z350 respectively. All sam- ples were stained for 24 hours after filling and observed by stereomicroscope and scanning electron microscopy. Part 2: Group A to B were filled with Composan LCM and FiltekTM Z350 respectively and light-cured. After 24 hours of light-cured, all the specimens were used the micro-hardness method to detect the curing efficiency. Results: The micro-leakage of group B was significantly higher than that of group A(P<0.05). SEM showed that there are visible cracks between the filling materials of group B and the dental tissue, and the in- terface is uneven with discontinuous small fractures. The interface of group A was continuous and uniform without obvious cracks, there was no significant difference in curing efficiency with different filling materials(P>0.05). Conclusion: Composan LCM and FiltekTM Z350 were suitable for primary carious cavities, and using Composan LCM had less micro-leakage than FiltekTM Z350.
查看全文   查看/发表评论  下载PDF阅读器
关闭