Article Summary
王辽菊,朱丽红,高 玮,王丽鸽,魏 珂.不同声强超声对孕鼠子宫收缩及胎鼠神经损伤的影响及机制[J].现代生物医学进展英文版,2019,19(12):2248-2251.
不同声强超声对孕鼠子宫收缩及胎鼠神经损伤的影响及机制
Effect and Mechanism of Different Intensity of Ultrasound on the Uterine Contraction of Pregnant Rats and the Nerve Injury of Fetal Rats
Received:November 10, 2018  Revised:December 02, 2018
DOI:10.13241/j.cnki.pmb.2019.12.010
中文关键词: 孕鼠  声强  超声  子宫收缩  神经损伤
英文关键词: Pregnant rats  Intensity  Ultrasound  Uterine contraction  Nerve injury
基金项目:国家自然科学基金项目(81072940)
Author NameAffiliationE-mail
WANG Liao-ju Department of obstetrics and gynecology, Xianyang First People's Hospital of Shaanxi Province, Xianyang, Shaanxi, 712000, China wangliaoju_1974@sina.com 
ZHU Li-hong Department of obstetrics and gynecology, Second Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine, Xianyang, Shaanxi, 712000, China  
GAO Wei Department of obstetrics and gynecology, Xianyang First People's Hospital of Shaanxi Province, Xianyang, Shaanxi, 712000, China  
WANG Li-ge Department of obstetrics and gynecology, Xianyang First People's Hospital of Shaanxi Province, Xianyang, Shaanxi, 712000, China  
WEI Ke Department of obstetrics and gynecology, Xianyang First People's Hospital of Shaanxi Province, Xianyang, Shaanxi, 712000, China  
Hits: 898
Download times: 787
中文摘要:
      摘要 目的:探讨不同声强超声对孕鼠子宫收缩及胎鼠神经损伤的影响及机制。方法:将32只孕鼠随机分为A(0)组、B(2)组、C(4)组、D(8)组,每组各8只,分别接受声强为0 W cm-2、2 W cm-2、4 W cm-2和8 W cm-2的超声辐照20 min。记录孕鼠子宫收缩及子宫平滑肌ATP酶的活力,检测胎鼠大脑皮层与海马神经元凋亡及胆碱能神经系统相关酶的活力。结果:超声增加孕鼠子宫收缩频率、收缩幅度、收缩张力和子宫活动度(P均<0.05),降低孕鼠子宫平滑肌中钠钾ATP酶、钙ATP酶和钙镁ATP酶的活性(P均<0.05)。超声降低胎鼠大脑皮层和海马中Bcl-2水平(P<0.05),增加Bax和Caspase-3水平(P均<0.05)。以及促进乙酰胆碱酯酶活力,降低乙酰胆碱和乙酰胆碱转移酶水平(P均<0.05)。且4 W cm-2和8 W cm-2的超声比2 W cm-2超声对这些指标的作用更强。结论:4 W cm-2和8 W cm-2超声可能通过降低ATP酶的活性促进孕鼠子宫平滑肌收缩,并可引起胎鼠大脑皮层和海马神经元损伤,机制可能与胆碱能神经元系统失衡有关,2 W cm-2声强的超声对胎鼠神经元损伤甚小。
英文摘要:
      ABSTRACT Objective: To determine the effect and mechanism of ultrasound with different intensity on uterine contraction of pregnant rats and nerve injury of fetal rats. Methods: 32 pregnant rats were randomly divided into A(0) group, B(2) group, C(4) group and D(8) group, with 8 rats in each group. Rats in these groups were respectively received ultrasonic irradiation with different intensities of 0 W cm-2, 2 W cm-2, 4 W cm-2 and 8 W cm-2 for 20 min. The uterine contraction and ATPase activities of uterine smooth muscle were recorded in pregnant rats, and neuronal apoptosis and activities of cholinergic nervous system-related enzymes in cerebral cortex and hippocampus were detected in fetal rats. Results: Ultrasound increased frequency, amplitude, tension and activity of uterine contraction (P<0.05), and decreased the activities of Na+-K+ ATPase, Ca2+ ATPase and Ca2+-Mg2+ ATPase in uterine smooth muscle of pregnant rats (P<0.05). Ultrasound reduced Bcl-2 levels (P<0.05) and increased the levels of Bax and Caspase-3 (P<0.05) in the cerebral cortex and hippocampus of fetal rats. Ultrasound promoted acetylcholinesterase activity, and reduced acetylcholine and acetylcholine transferase levels (P<0.05). Ultrasounds with 4 W cm-2 and 8 W cm-2 were more effective than with 2 W cm-2 ultrasound on the effect of these indicators. Conclusion: 4 W cm-2 and 8 W cm-2 might promote the contraction of uterine smooth muscle in pregnant rats through reducing the activity of ATPases, and resulting in damage to cerebral cortex and hippocampal neurons of fetal rats, the mechanism may be associated with the imbalance of the cholinergic neuron system. 2 W cm-2 Ultrasound has little damage to fetal rat neurons.
View Full Text   View/Add Comment  Download reader
Close