Article Summary
王建锋,乔玉玲,秦海燕,崔保峰,南建军,毛晓燕.应用CE-SDS测定抗CD52人源化单克隆抗体参比品单体纯度及非糖化重链比例[J].现代生物医学进展英文版,2018,(15):2836-2840.
应用CE-SDS测定抗CD52人源化单克隆抗体参比品单体纯度及非糖化重链比例
CE-SDS were Applied to Determine Monomer Purity and Proportion of Non-glycosylated Heavy Chain in Reference Products of anti-CD52 Humanized Monoclonal Antibody
Received:December 28, 2017  Revised:January 23, 2018
DOI:10.13241/j.cnki.pmb.2018.15.007
中文关键词: 十二烷基苯硫酸钠-毛细管电泳  抗CD52人源单抗  单体纯度  非糖化重链比例
英文关键词: CE-SDS  Anti-CD52 humanized monoclonal antibody  Monomer purity  Non-glycosylated heavy chain proportion
基金项目:甘肃省科技厅重大专项(1502FKDA008)
Author NameAffiliationE-mail
王建锋 兰州生物制品研究所有限责任公司甘肃省大分子蛋白生物药工程研究中心甘肃省疫苗工程技术研究中心 甘肃 兰州 730046 jfwang2003@163.com 
乔玉玲 兰州生物制品研究所有限责任公司甘肃省大分子蛋白生物药工程研究中心甘肃省疫苗工程技术研究中心 甘肃 兰州 730046  
秦海燕 兰州生物制品研究所有限责任公司甘肃省大分子蛋白生物药工程研究中心甘肃省疫苗工程技术研究中心 甘肃 兰州 730046  
崔保峰 兰州生物制品研究所有限责任公司甘肃省大分子蛋白生物药工程研究中心甘肃省疫苗工程技术研究中心 甘肃 兰州 730046  
南建军 兰州生物制品研究所有限责任公司甘肃省大分子蛋白生物药工程研究中心甘肃省疫苗工程技术研究中心 甘肃 兰州 730046  
毛晓燕 兰州生物制品研究所有限责任公司甘肃省大分子蛋白生物药工程研究中心甘肃省疫苗工程技术研究中心 甘肃 兰州 730046  
Hits: 614
Download times: 405
中文摘要:
      摘要 目的:测定抗CD52人源单克隆抗体参比品单体纯度及非糖基化重链比例。方法:采用PA800 plus毛细管电泳系统,非还原十二烷基苯硫酸钠-毛细管电泳(CE-SDS)测定抗CD52人源单克隆抗体单体纯度,以及用还原CE-SDS电泳测定非糖化重链比例。结果:非还原CE-SDS三次测定单体纯度平均值为93.57%,主峰的迁移时间及修正峰面积百分比RSD分别为0.16%和0.19%;还原CE-SDS电泳重链修正峰面积百分比平均值为66.89%,修正峰面积百分比及迁移时间RSD分别为0.09%和0%;轻链修正峰面积百分比平均值为32.30%;轻链修正峰面积及迁移时间RSD分别为0%和0%;非糖基化重链修正峰面积百分比平均值为0.87%,修正峰面积百分比及迁移时间RSD分别为6.66%和0.27%。结论:CE-SDS测定抗CD52人源单抗单体纯度及非糖化重链比例实验结果偏差较小,表明结果准确可靠。
英文摘要:
      ABSTRACT Objective: To determine the monomer purity and proportion of non-glycosylated heavy chain in reference productsanti- CD52 humanized monoclonal antibody. Methods: Using PA800 plus capillary electrophoresis system, Non-reduced CE-SDS were ap- plied to determine monomer purity and reduced CE-SDS were applied to determine non-glycosylated heavy chain in anti-CD52 human- ized monoclonal antibody. Results: Average value of monomer purity is 93.57% by Non-reduced CE-SDS in three times, RSD of migra- tion time of main peak and corrected area percent were 0.16% and 0.19% respectively. Average value of heavy chain corrected area per- cent is 66.89% by reduced CE-SDS in three times, RSD of migration time and corrected area percent of main peak were 0.09% and 0% respectively. Average value of light chain corrected area percent is 32.30% by reduced CE-SDS in three times, RSD of corrected area percent and migration time of main peak were 0% and 0% respectively. Average value of non-glycosylated heavy chain corrected area percent is 0.87% by reduced CE-SDS in three times, RSD of corrected area percent and migration time of main peak were 6.66% and 0.27% respectively. Conclusion: The data of using CE-SDS determine the monomer purity and proportion of non-glycosylated heavy chain in anti-CD52 humanized monoclonal antibody displayed a much small RSD, and manifested the result were accurate and reliable.