Objective:To investigate the effective of treating tibial eminence fracture in suture andwire fixation on arthroscopic.Methods:87 patients of tibial eminence fracture cases collected from Jun 2012 to Dec 2013 in our hospital, which were divided into
groupA (n=40), group (37 cases)B according ways of fixation, which group A was given suture fixation, and group B wire fixation,
observing reset condition after 3, 6, 12 months, including healing time, assess knee function, range of motion of the knee, surgery time
and complications.Results:Preoperative and postoperative 3 months between Lysholm score was no significant difference (P>0.05), 6
and 12 months the difference was statistically significant (P<0.05); The two groups of Lysholm score were gradually increased in
preoperative,comparative with postoperative, and the difference was statistically significant (P<0.05); Operative time had no significant
difference in two groups (P>0.05), and patients knee a range of motion of the comparative group of patients was significantly better than
group B(P<0.05),and healing time ofA group shorter than group B group(P<0.05).Conclusion:Arthroscopic suture fixation between the
tibial eminence fracture with less trauma, simple, fixed solid, beneficial joint early rehabilitation, can be widely used. |