Article Summary
高嘉锴 贾帅 袁志 孟国林 毕龙 段春光 程建岗 刘建△.2D导航辅助经皮骶髂螺钉治疗骨盆后环骨折经验分析[J].现代生物医学进展英文版,2016,16(19):3668-3672.
2D导航辅助经皮骶髂螺钉治疗骨盆后环骨折经验分析
Fluoro-navigation Screw Fixation for the Treatment of Posterior Pelvic Ring Injuries
  
DOI:
中文关键词: 骨盆骨折  透视导航  经皮内固定  骶骨螺钉
英文关键词: Pelvic fracture  Fluoro-navigation  Percutaneous fixation  Iliosacral screw
基金项目:国家自然科学基金项目(30901532, 81371982)
Author NameAffiliation
高嘉锴 贾帅 袁志 孟国林 毕龙 段春光 程建岗 刘建△ 第四军医大学西京医院创伤骨科 
Hits: 886
Download times: 0
中文摘要:
      目的:观察C 型臂透视2D导航引导下经皮骶髂螺钉治疗骨盆后环不稳定型骨折的手术安全性和临床效果。方法:2011 年1 月-2013 年12 月采用二维透视导航辅助经皮置入骶髂螺钉治疗C 型(Tile 分型)骨盆骨折患者22 例,其中交通伤16 例,坠落伤 4例,重物砸伤2 例。伤后就诊时间5 h~12d(平均20 h)。按照骨盆骨折Tile 分型:B3.3 型1 例,C1.2 型8 例,C1.3 型12 例,C3.3 型1 例。其中伴有休克2 例,腹部损伤3 例,尿道损伤4 例,脊柱损伤5 例,骶神经损伤1 例,胫骨骨折2 例。结果:建立导航系统 耗时13~30 min(平均18.50± 6.20 min),每枚螺钉置入耗时15~25 min(平均17.50± 7.20 min),置入每枚螺钉出血量约20 mL。所 有患者螺钉置入位置均较满意,无穿透椎弓根或椎体骨皮质进入骶孔、骶管和前方的盆腔等现象出现,无伤口感染发生。采用 Matta 评分标准评价骨折复位情况:优15 例,良5 例,可2 例。采用Majeed 评分行功能评价:优13 例,良6 例,可3 例。结论:采用 导航下骶髂螺钉固定技术能够有效恢复骨盆后环稳定性,但需要手术者熟练掌握骨盆解剖结构及生物力学特点,有效增加手术 准确性,避免副损伤。
英文摘要:
      Objective:To evaluate the application of fluoroscopy navigation-assisted percutaneous screw fixation of unstable posterior pelvic ring trauma.Methods:From January 2011 to December 2013, 22 patients with posterior pelvic ring injuries were included. All patients were treated with percutaneous screw fixation using an optoelectronic fluoroscopy navigation system. In all the 22 patients, 16 were injured by traffic accident, 4 were injured by high-altitude falling and 2was injured by crashing object. According to Tile classification, there were 1 cases ofB 3.3 type, 8 cases ofC 1.2 type, 12 cases of C 1.3 type, 1 cases ofC 3.3 type.Results:Mean operation time for each screw was 18.50± 6.20 min. The mean blood loss for each screw was 20 mL. The postoperative X ray and three dimensional CT showed that the fractures had good reduction and all the screws had good position. No screw misplacement and no wound infections was observed. Using the rating system of Matta, 15 patients had excellent results, 5 patients had good results, and 2 patients had a fair result. According to Majeed functional scoring, 13 patients had the excellent results, 6 patients had good results, and 3 patients had fair results.Conclusion:Our results showed that fluoroscopy-based navigation technique for the pelvic ring injuries could become a safe and effective method for the treatment of posterior pelvic ring injuries.
View Full Text   View/Add Comment  Download reader
Close