张玉兰 陈丹 李军 张庆国 殷雁斌.腰硬联合麻醉对围手术期剖宫产患者皮质醇及血浆D-D水平的影响[J].现代生物医学进展英文版,2016,16(10):1891-1893. |
腰硬联合麻醉对围手术期剖宫产患者皮质醇及血浆D-D水平的影响 |
Effect of Continuous Epidural Anesthesia and Combined Spinal EpiduralAnesthesia on the Perioperative Plasma Cortisol and D-dimer Levels ofPatients with Caesarean |
|
DOI: |
中文关键词: 连续硬膜外麻醉 腰硬联合麻醉 皮质醇 D-二聚体 |
英文关键词: Continuous epidural anesthesia Combined spinal epidural anesthesia Cortisol D-dimer |
基金项目:广东省科技计划项目(2012B031800264);成都军区十二五重点项目(B14010) |
|
Hits: 929 |
Download times: 0 |
中文摘要: |
目的:探讨腰硬联合麻醉(CSEA)对剖宫产围术期患者围术期皮质醇及血浆D- 二聚体(D-D)水平变化的影响。方法:选取
2014 年3 月-2015 年5 月在我院接受剖宫产手术的患者68 例为研究对象。.根据术中采用的麻醉方法不同,将患者分为腰硬联合
麻醉组(CSEA组)和连续硬膜外麻醉组(CEA 组)。观察并比较两组患者围手术期皮质醇及D-二聚体水平的变化情况。结果:两
组患者术中纤维蛋白原、凝血活酶时间及凝血酶原时间间比较,差异均无统计学意义(P>0.05);两组患者麻醉后皮质醇及D-D 水
平均显著高于麻醉前,但CSEA 组低于CEA 组,差异具有统计学意义(P<0.05);两组患者D-D 水平在手术结束时、术后24 h较麻
醉前均显著升高,差异有统计学意义(P<0.05);但CSEA 组D-D 水平在术后24 h及、术后72 h,CSEA 组D-D 水平均低于CEA
组,差异具有统计学意义(P<0.05)。结论:腰硬联合麻醉可以更好的抑制剖宫产患者术中血清皮质醇及术后血浆D-D 水平的升
高,有利于改善患者术后高凝状态,值得临床推广应用。 |
英文摘要: |
Objective:To explore the effect of continuous epidural anesthesia (CEA) and combined spinal epidural anesthesia
(CSEA) on the perioperative plasma cortisol and D-dimer (D-D) levels in caesarean section.Methods:69 cases of caesarean section were
selected who were treated in our hospital from March June 2014 to May June 2015 were selected as research objects and according to
the different methods, the patients were, which were divided into the CSEA group and the CEA group. observed group (36 cases) and
control group (33 cases). Patients in CSEA observed group undergone CSEA and patients in CEA group undergone CEA. Then the
levels of perioperative plasma cortisol and D-D between two groups were detected and compared.Results:There was no statistically
significant difference about the levels of intraoperative fibrinogen, and the time of activated partial thromboplastin time and prothrombin
time had no significant difference between two groups (P>0.05); The levels of plasma cortisol and D-D after anesthesia was significantly
higher than that before anesthesia in both two groups, and the CESA group was lower than those of the CEA group, and the difference
was statistically significant (P<0.05), but CESA group was lower than CEA group, ; D-D level of both groups at the end of surgery and 24
h after surgery was all significant higher than before anesthesia, and the difference was statistically significant (P<0.05); the D-D level of
CESA group was lower than CEA group 24 h and 72 h after surgery when compared with before, and the difference was statistically
significant (P<0.05).Conclusion:CSEA can better inhibit the levels of serum cortisol and plasma D-D of patients with cesarean section
when compared with CEA, which can be more conducive to improve postoperative blood high condensation state. |
View Full Text
View/Add Comment Download reader |
Close |