产前超声诊断及漏诊胎儿肢体畸形分析 |
Analysis of Prenatal Ultrasound Diagnosis and Missed Diagnosis of FetalLimb Deformities |
|
DOI: |
中文关键词: 胎儿 超声 肢体畸形 |
英文关键词: Fetus Ultrasound Limb deformity |
基金项目: |
|
Hits: 872 |
Download times: 1348 |
中文摘要: |
摘要 目的: 探讨胎儿肢体畸形超声特征及诊断价值。 方法: 采用连续顺序追踪法对 66342 例妊娠 12-40 周孕妇行胎儿四肢畸形筛
查。 将产前超声诊断结果与引产或产后结果进行对比分析。 结果: 发生肢体畸形 271 例, 发生率为 0.41% ( 271/66342 ) ,包括四肢短
小 5 例, 桡骨发育不全 1 例, 缺肢畸形 5 例, 足内翻 17 例, 手掌畸形 3 例, 指趾畸形 222 例及骨骼多发畸形 18 例。其中产前诊断
胎儿肢体畸形 49 例; 漏诊 222 例, 包括: 足内翻 3 例、 指趾畸形 218 例、 多发骨骼畸形 1 例。胎儿肢体畸形的出现率和产前检出率
分别为: 四肢短小 1.84% (5/271 ) 、 100% ( 5/5 ) ; 桡骨发育不全 0.36% (1/271 ) 、 100% ( 1/1 ) ; 缺肢畸形 1.84% ( 5/271 ) 、 100% (5/5 ) ;
足内翻 6.27% ( 17/271 ) 、 82.35% ( 14/17 ) ; 手掌畸形 1.10% ( 3/271 ) 、 100% (3/3 ) ; 指趾畸形 81.91% ( 222/217 ) 、 1. 8% (4/222 ) ; 多发
骨骼畸形 6.64% (18/271 ) 、 94.44% (17/18 )。 结论: 超声对胎儿手掌、 脚掌部位以上畸形的检出率较高。 指趾畸形出现率最高, 但检
出率最低。 |
英文摘要: |
ABSTRACT Objective:This study was to investigate the ultrasonic characteristics and its value for fetal limb deformities.
Methods:Systematic continuous sequence approach was performed to observe fetal limbs and fetal limb deformities for 66,342 cases of pregnancy
in 12-40 weeks. The prenatal diagnosis results were analyzed and compared with postnatal results. Results:Two hundred and seventy-one
cases in 66,342 fetuses occurred limb deformities (incidence rate as 0.41% ) including five cases of short limbs, one case of radial
hypoplasia, five cases of ectromelia, 17 cases of strephenopodia, 3 cases of palm deformities, 222 cases of fingers and toes deformities,
17 cases of multiple skeletal deformities. Forty-nine cases of fetal limb deformities were diagnosed by prenatal ultrasound and 222 cases
were missed including 3 cases of strephenopodia, 218 cases of fingers and toes deformities, 1 case of multiple skeletal deformities. The
frequency and prenatal detection rate of fetal limb deformities were: short limbs 1.84 % (5/271) and 100 % (5/5); radial hypoplasia 0.36
% (1/271) and 100 % (1/1); ectromelia 1.84 % (5/271) and 100 % (5/5); strephenopodia 6.27 % (17/271) and 82.35 % (14/17); palm
deformity 1.10 % (3/271) and 100 % (3/3); fingers and toes deformities 81.91 % (222/217) and 1.8 % (4/222); multiple skeletal
deformities 6.64 % (18/271) and 94.44 % (17/18).Conclusion: The detection rate of prenatal ultrasound was very high for the limb
deformities above fetal palms and soles. Fingers and toes deformities hada high incidence rate but a very low detection rate. |