Article Summary
左拥军田树平赵书臣邵立新史丽静.常规腹部立位平片漏诊膈下游离气体原因分析及技术改进[J].现代生物医学进展英文版,2011,11(14):2750-2751.
常规腹部立位平片漏诊膈下游离气体原因分析及技术改进
Analysis of Negative Findings of Standing Abdominal Plain Film inPneumoperitoneum and Its Technical Impovements
  
DOI:
中文关键词: 膈下游离气体  气腹  胸片  腹部立位平片
英文关键词: Pneumoperitoneum  Chest X-ray  Standing abdominal Plain film
基金项目:
Author NameAffiliation
ZUO Yong-jun, TIAN Shu-ping, ZHAO Shu-chen, SHAO Li-xin, SHI Li-jing 海军总医院放射科 
Hits: 889
Download times: 1961
中文摘要:
      目的:探讨常规腹部立位平片漏诊膈下游离气体的原因及技术改进。方法:15 例疑有气腹但腹部立位平片阴性者加拍胸部 正位片,观察有无膈下游离气体。结果:15 例中12 例胸片可显示膈下少量游离气体。结论:X 线投照中心线位置不同会影响膈下 游离气体的显示,胸片较腹部立位平片更容易显示少量气腹。
英文摘要:
      Objective: To analyse the reason of negative result of the standing abdominal plain film in pneumoperitoneum, compared with the chest X-ray film. Methods: A total of 15 patients ,who were suspected with pneumoperitoneum,underwent chest X-ray if their standing abdominal plain films were negative.Results: 12 of the 15patients got positive findings in their chest X-ray film, free gases under the diaphragm were found. Conclusion: The position of centrage could influnce the display of pneumoperitoneum when the gases under the diaphragm was too little. Chest X-ray has more advantage than standing abdominal plain film.
View Full Text   View/Add Comment  Download reader
Close