文章摘要
尹光宇 明皓 张光华 任卫东 李华.常规高频超声联合超声弹性成像在甲状腺良恶性结节鉴别诊断中的应用价值[J].,2016,16(20):3894-3897
常规高频超声联合超声弹性成像在甲状腺良恶性结节鉴别诊断中的应用价值
The Application Value of Conventional High Frequency Ultrasound andUltrasound Elastography in the Identification of Benign and MalignantThyroid Nodule
  
DOI:
中文关键词: 常规高频超声  超声弹性成像  甲状腺  良恶性结节
英文关键词: Conventional high frequency ultrasound  Ultrasound elastography  Thyroid  Benign and malignant nodules
基金项目:辽宁省科技厅科学技术计划项目(2013225049)
作者单位
尹光宇 明皓 张光华 任卫东 李华 辽宁中医药大学附属医院超声心电中心 沈阳煤业集团总医院内分泌科中国医科大学附属盛京医院超声科 
摘要点击次数: 1044
全文下载次数: 0
中文摘要:
      目的:研究常规高频超声与超声弹性成像在甲状腺结节良恶性鉴别诊断中的应用价值。方法:选择住院的甲状腺结节性疾病 患者120 例(146 个甲状腺结节)。对患者进行常规高频超声和超声弹性成像检查,以术后病理检查为金标准,计算不同方法对甲 状腺良恶性结节鉴别诊断的灵敏度、特异度、准确度。结果:120 例患者,经手术病理检查证实有146个结节,其中良性结节98 个, 恶性结节48 个。常规高频超声显示在形态、边界、包膜、内部回声、微钙化及RI值上,甲状腺良、恶性结节之间的差异有统计学意 义(P<0.05)。常规高频超声与弹性成像相比,诊断效能之间的差异无统计学意义(P>0.05);常规高频超声与联合超声诊断的灵敏 度(X2=12.22,P<0.01)、特异度(X2=10.21,P<0.01)、准确度(X2=9.31,P<0.01)相比较,差异具有统计学显著性;超声弹性成像与联合 超声诊断灵敏度(X2=6.51,P<0.01)、特异度(X2=5.82,P<0.05)、准确度(X2=4.56,P<0.05)相比,差异具有统计学显著性。结论:常规 高频超声联合超声弹性成像对甲状腺良恶性结节的诊断灵敏度和准确度高,值得进一步推广临床应用。
英文摘要:
      Objective:To investigate the application value of conventional high frequency ultrasound and ultrasound elastography in the identification of benign and malignant thyroid nodules.Methods:120 inpatients with thyroid nodular disease (146 thyroid nodules) were selected. The patients were examined by conventional high frequency ultrasound and ultrasound elastography. The sensitivity, specificity and accuracy of different methods on the diagnosis of benign and malignant thyroid nodules were calculated, with postoperative pathologic examination as the gold standard.Results:146 nodules were confirmed by surgery pathology examination in 120 patients, including 98 benign nodules, 48 malignant nodules. Conventional high frequency ultrasound showed that the difference on the shape, border, coated, internal echo, micro calcification and RI values between the benign nodules and malignant nodules was statistically significant (P< 0.05). Comparing the diagnostic efficiency of conventional high frequency ultrasonography with ultrasound elastography, there was no statistical significance (P > 0.05); Comparing the sensitivity(X2= 12.22, P < 0.01), specificity(X2 = 10.21, P < 0.01) and accuracy (X2 = 9.31, P< 0.01) of conventional high frequency ultrasonography with combined ultrasonic diagnosis, there were statistically significant differences; Comparing the sensitivity(X2= 6.51, P < 0.01), specificity(X2= 5.82, P< 0.05) and accuracy(X2= 4.56, P < 0.05) of ultrasound elastography with combined ultrasonic diagnosis, the differences were statistically significant.Conclusion:The identification of conventional high frequency ultrasonography combined with ultrasonic elastography in the diagnosis of benign and malignant thyroid nodule had high sensitivity and accuracy, worthy of further promotion of clinical application.
查看全文   查看/发表评论  下载PDF阅读器
关闭