左拥军田树平赵书臣邵立新史丽静.常规腹部立位平片漏诊膈下游离气体原因分析及技术改进[J].,2011,11(14):2750-2751 |
常规腹部立位平片漏诊膈下游离气体原因分析及技术改进 |
Analysis of Negative Findings of Standing Abdominal Plain Film inPneumoperitoneum and Its Technical Impovements |
|
DOI: |
中文关键词: 膈下游离气体 气腹 胸片 腹部立位平片 |
英文关键词: Pneumoperitoneum Chest X-ray Standing abdominal Plain film |
基金项目: |
|
摘要点击次数: 926 |
全文下载次数: 2017 |
中文摘要: |
目的:探讨常规腹部立位平片漏诊膈下游离气体的原因及技术改进。方法:15 例疑有气腹但腹部立位平片阴性者加拍胸部
正位片,观察有无膈下游离气体。结果:15 例中12 例胸片可显示膈下少量游离气体。结论:X 线投照中心线位置不同会影响膈下
游离气体的显示,胸片较腹部立位平片更容易显示少量气腹。 |
英文摘要: |
Objective: To analyse the reason of negative result of the standing abdominal plain film in pneumoperitoneum, compared
with the chest X-ray film. Methods: A total of 15 patients ,who were suspected with pneumoperitoneum,underwent chest X-ray if
their standing abdominal plain films were negative.Results: 12 of the 15patients got positive findings in their chest X-ray film, free gases
under the diaphragm were found. Conclusion: The position of centrage could influnce the display of pneumoperitoneum when the gases
under the diaphragm was too little. Chest X-ray has more advantage than standing abdominal plain film. |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |