文章摘要
曹云太,尹桂秀,栗海龙,严小红,鲍海华.能谱CT优化胃肿瘤扫描辐射剂量对肾上腺嗜铬细胞瘤的诊断价值[J].,2018,(22):4342-4345
能谱CT优化胃肿瘤扫描辐射剂量对肾上腺嗜铬细胞瘤的诊断价值
Diagnostic Value of Spectrum CT Optimized Gastric Tumor Scanning Radiation Dose for Adrenal Pheochromocytoma
投稿时间:2018-02-23  修订日期:2018-03-18
DOI:10.13241/j.cnki.pmb.2018.22.032
中文关键词: 能谱CT  胃肿瘤扫描  肾上腺嗜铬细胞瘤  辐射剂量  图像噪声
英文关键词: Spectrum CT  Gastric tumor scan  Adrenal pheochromocytoma  Radiation dose  Image noise
基金项目:青海省科技厅科研基金项目(2017-SF-158)
作者单位E-mail
曹云太 青海大学附属医院影像中心 青海 西宁 810001 caoyuntai_1986@papmedline.cn 
尹桂秀 青海大学附属医院影像中心 青海 西宁 810001  
栗海龙 青海大学附属医院影像中心 青海 西宁 810001  
严小红 青海大学附属医院重症医学科 青海 西宁 810001  
鲍海华 青海大学附属医院影像中心 青海 西宁 810001  
摘要点击次数: 492
全文下载次数: 264
中文摘要:
      摘要 目的:探讨能谱CT优化胃肿瘤扫描辐射剂量对肾上腺嗜铬细胞瘤的诊断价值。方法:采用回顾性、抽样、随机研究方法选择2012年9月到2017年2月在我院诊治的肾上腺嗜铬细胞瘤患者59例作为研究对象,所有患者都给予常规CT扫描与能谱CT优化胃肿瘤扫描,记录和比较辐射剂量与图像质量。结果:所有病例包膜均完整,边缘清楚,肿瘤内见单发或多发低密度区,肿瘤实质区呈不均匀显著强化。常规CT与能谱CT的图像质量主观评分分别为3.89±0.45分和4.54±0.34分;常规CT与能谱CT图像的胃肿瘤CT值分别为31.94±6.39HU和35.29±5.19HU,对比都有显著差异(P<0.05)。能谱CT图像的膀胱和皮下脂肪图像噪声值都显著低于常规CT图像,对比差异都有统计学意义(P<0.05);能谱CT扫描的CTDIvol和DLP分别为12.39±3.48mGy和624.10±39.19mGy.cm,都显著低于常规CT扫描的14.09±4.13mGy和653.92±56.29mGy.cm(P<0.05)。结论:能谱CT优化胃肿瘤扫描在肾上腺嗜铬细胞瘤诊断中的应用能有效减少辐射剂量与图像噪声,提高图像CT值与主观质量,临床应用价值更高。
英文摘要:
      ABSTRACT Objective: To explore the diagnostic values of spectrum CT optimized gastric tumor scanning radiation dose for adrenal pheochromocytoma. Methods: A retrospective, randomized study was performed from September 2012 to February 2017, 59 patients of adrenal pheochromocytoma in our hospital were selected as the research object, all patients were given spectrum CT optimized gastric tumor scanning and conventional CT scanning, the radiation dose and image quality were recorded and compared. Results: All patients were showed intact, the edges were clear, single or multiple low density areas were found in the tumor, and the tumor parenchyma were inhomogeneous and significantly enhanced. The subjective scores of image quality of conventional CT and spectrum CT were 3.89±0.45 points and 4.54±0.34 points, respectively. The CT values of gastric tumors in routine CT and spectrum CT images were 31.94± 6.39HU and 35.29±5.19HU, respectively, with compared were significantly difference (P<0.05). The bladder and subcutaneous fat image noise values in the spectrum image CT were significantly lower than that of the conventional CT image, the difference were statistically significant (P<0.05); The CTDIvol and DLP in the spectrum image CT were 12.39±3.48mGy and 624.10±9.19 mGy.cm were significantly lower than that of the conventional image CT of 14.09±4.13mGy and 653.92mGy±56.29mGy.cm (P<0.05). Conclusion: Spectrum CT optimized gastric tumor scanning radiation dose can effectively radiate dose and image noise, improve image CT and subjective quality for adrenal pheochromocytoma, and it has a good application value.
查看全文   查看/发表评论  下载PDF阅读器
关闭